Cited Article: Sokhan VP. Fluid flow in nanopores: Accurate boundary conditions for carbon nanotubes
Alert Expires: 18 OCT 2009
Number of Citing Articles: 1 new records this week (1 in this e-mail)
Organization ID: 3b97d1bbc1878baed0ab183d8b03130b
========================================================================
Note: Instructions on how to purchase the full text of an article and Help Desk Contact information are at the end of the e-mail.
========================================================================

*Record 1 of 1.
*View Full Record: http://gateway.isiknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS&DestLinkType=FullRecord;KeyUT=000266546900083
*Order Full Text [ ]

Title:
INVESTIGATION OF TEMPERATURE DRIVEN GAS FLOWS IN 4 NM CHANNELS FOR APPLICATIONS OF MICRO-SCALE COMPRESSORS AT ABOVE ATMOSPHERIC PRESSURE

Authors:
Han, YL; Muntz, EP

Author Full Names:
Han, Yen-Lin; Muntz, E. P.

Source:
PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 13, PTS A AND B : 661-668 2009

Language:
English

Document Type:
Proceedings Paper

KeyWords Plus:
LINEARIZED BOLTZMANN-EQUATION; WALL CARBON NANOTUBES; MOLECULAR-TRANSPORT; KNUDSEN COMPRESSOR; MEMBRANES; PERFORMANCE

Abstract:
Based on the rarefied flow phenomenon of thermal creep (or thermal transpiration), the Knudsen Compressor is an unconventional micro/meso-scale compressor or pump. Optimization studies have shown that a Knudsen Compressor operates most efficiently when its membrane's flow channels are at the transitional flow regime, between continuum and molecular flows; simultaneously it provides a desired mass flow and pressure ratio. At higher pressures (> 1 atm), to maintain membrane channel Knudsen numbers in the transitional regime (Kn similar to 1), the corresponding membrane channel size needs to be less than about 50 nm. More specifically, at 10 atm, the membrane channel size should be as small as 5 rim to provide the most efficient Knudsen Compressor operation.
Prior to this work, there has been no documented experimental investigation of thermal creep measurements through channels less than 5 nm. Phenomena that could be associated with such flows are briefly discussed, and possible selection criteria for thermal creep membranes are included in this study. Apparatus design is discussed. Experimental results are provided for thermal creep flows, within a single stage Knudsen Compressor with 4 nm diameter membrane channels. The maximum pressure increases across the Knudsen Compressor's thermal creep membrane were measured, over a range of operating pressures from I atm to 1.1 atm with Helium or Argon as the working gas. Results showed apparent thermal creep effects across the porous glass membrane, and possibly significant force field effects within the nano-scale channels.

Reprint Address:
Han, YL, Univ So Calif, Los Angeles, CA 90089 USA.

Research Institution addresses:
[Han, Yen-Lin; Muntz, E. P.] Univ So Calif, Los Angeles, CA 90089 USA

Cited References:
ACKERMAN DM, 2003, MOL SIMULAT, V29, P677, DOI 10.1080/0892702031000103239.
ARORA G, 2006, J CHEM PHYS, V124, P84702, ARTN 084702.
BEENAKKER JJM, 1994, PHYS REV LETT, V72, P514.
BEENAKKER JJM, 1995, CHEM PHYS LETT, V232, P379.
BORMAN VD, 1990, SOV PHYS JETP, V70, P1013.
CHEN HB, 2006, J PHYS CHEM B, V110, P1971, DOI 10.1021/jp056911i.
FUJII M, 2005, PHYS REV LETT, V95, P5502.
HAN YL, 2004, THESIS U SO CALIFORN.
HAN YL, 2007, J VAC SCI TECHNOL B, V25, P703, DOI 10.1116/1.2723755.
HAN YL, 2007, NANOSC MICROSC THERM, V11, P151, DOI 10.1080/15567260701337209.
HAN YL, 2008, J MICROELECTROMECH S, V17, P984.
HINDS BJ, 2004, SCIENCE, V303, P62, DOI 10.1126/science.1092048.
HIRSCHFELDER JO, 1964, ADV QUANTUM CHEM, V1, P255.
HOLT JK, 2006, SCIENCE, V312, P1034, DOI 10.1126/science.1126298.
HONE J, 1999, PHYS REV B, V59, P2514.
JAKOBTORWEIHEN S, 2006, J CHEM PHYS, V124, P54706.
KNUDSEN M, 1910, ANN PHYS-BERLIN, V31, P205.
KNUDSEN M, 1910, ANN PHYS-BERLIN, V33, P1435.
LU GQ, 2004, NANOPOROUS MAT SCI E.
MAJUMDER M, 2005, NATURE, V438, P44, DOI 10.1038/43844a.
MARTIN CR, 2001, J PHYS CHEM B, V105, P1925.
MUNTZ EP, 2002, J VAC SCI TECHNOL A, V20, P214.
MUNTZ EP, 2002, MEMS HDB.
PADGETT CW, 2004, NANO LETT, V4, P1051, DOI 10.1021/nl049645d.
PHAMVANDIEP G, 1995, RAREFIED GAS DYN, P715.
REYNOLDS O, 1879, PHILOS T, V170, P727.
SHACKELFORD JF, 2001, CRC MAT SCI ENG HDB, P289.
SKOULIDAS AI, 2002, PHYS REV LETT, V89, P5901.
SOKHAN VP, 2002, J CHEM PHYS, V117, P8531, DOI 10.1063/1.1512643.
SOKHAN VP, 2004, J CHEM PHYS, V120, P3855, DOI 10.1063/1.1643726.
SONE Y, 1989, PHYS FLUIDS A-FLUID, V1, P363.
SONE Y, 1994, EUR J MECH B-FLUID, V13, P573.
SUGIMOTO H, 2005, AIP CONF PROC, V762, P168.
VARGO SE, 2000, THESIS U SO CALIFORN.
WANG YH, 2004, J AM CHEM SOC, V126, P9502, DOI 10.1021/ja048680j.
YOUNG MP, 2004, THESIS U SO CALIFORN.

Cited Reference Count:
36

Times Cited:
0

Publisher:
AMER SOC MECHANICAL ENGINEERS; THREE PARK AVENUE, NEW YORK, NY 10016-5990 USA

IDS Number:
BJJ80

========================================================================
*Order Full Text*
All Customers
--------------
Please contact your library administrator, or person(s) responsible for
document delivery, to find out more about your organization's policy for
obtaining the full text of the above articles. If your organization does
not have a current document delivery provider, your administrator can
contact ISI Document Solution at service@isidoc.com, or call 800-603-4367
or 734-459-8565.

IDS Customers
--------------
IDS customers can purchase the full text of an article (having page number,
volume, and issue information) by returning this ENTIRE message as a Reply
to Sender or Forward to orders@isidoc.com. Mark your choices with an X in
the "Order Full Text: []" brackets for each item. For example, [X].

Please enter your account number here:

========================================================================
*Help Desk Contact Information*
If you have any questions, please visit the Thomson Scientific Technical Support Contact Information Web page:
http://www.thomsonscientific.com/support/techsupport
========================================================================

No comments: